Replacement Filter Element for Van Air F200 Filter Housing. The (*) asterisk at the end of the part number designates the filtration grade. During checkout please advise the required filtration grade / media in the Notes Section.
Important Guidelines:
Change Element Grades AA, A, B, C, RAA, RA, RB, RC and HT before differential pressure reaches 10 psig.
Change Element Grade RD periodically as the application dictates, but at least once every six months. Note: Grade B and C prefilters required upstream of Grade RD for proper operation.
FILTRATION GRADES
Application | Element Grade | Purpose | Nominal Particulate Removal | Element Flow Direction | End Cap Color Code |
Aerosol Removal (Liquids) | AA | Extra Coarse Coalescing | 25.0 m | IN / OUT | Black |
A | Coarse Coalescing | 5.00 m | IN / OUT | Green | |
B | General Purpose Coalescing | 1.00 m | IN / OUT | Red | |
C | High Efficiency Coalescing | 0.01 m | IN / OUT | Blue | |
Solid Particulate Removal | RAA | Extra Coarse Coalescing | 25.0 m | OUT / IN | Black |
RA | Coarse Coalescing | 5.00 m | OUT / IN | Green | |
RB | General Purpose Coalescing | 1.00 m | OUT / IN | Red | |
RC | High Efficiency Coalescing | 0.01 m | OUT / IN | Blue | |
HT | High Temperature Particulate | 1.00 m | OUT / IN | Zinc Plate or Galvanized | |
Oil Vapor Removal | RD | Vapor Adsorbing | 0.01 m | OUT / IN | Black |
|
|