Van Air F200-15-1/4 Compressed Air Filter - 1/4" - 15 CFM

(No reviews yet) Write a Review
SKU:
F200-15-1/4
Now: $420.00
Was: $475.00
Frequently bought together:

Description

The Van Air F200-15-1/4 Filter Housing is good for 15 SCFM at 100 PSIG and has 1/4" NPT connections. The filter element and manual drain valve are included in the price.

All Van Air F200 Series filter housings are cast aluminum and coated with epoxy powder coating to resist corrosion. The filter head also includes a pop-up pressure differential indicator as standard equipment. This differential indicator is used as a visual indicator of when the filter element needs to be changed. With 14 housing sizes, 9 types of filtration grades, and a maximum working pressure of 250 PSIG at 225° F, our F200 Series filters will satisfy the most unique and demanding needs.

Van Air F200 Series compressed air filter housings are capable of automatic or manual draining. All F200 Series housings are equipped with a ball type manual drain valve as standard equipment. However, a Van Air automatic drain valve can be installed to automatically drain the filter when needed. This will prevent the filter housing from flooding, causing filter element damage and contaminating the air system. Additional accessories for the F200 Series compressed air filter housings include other differential pressure indicators, wall mounting kits, and connector kits.

  • Flows up to 15 SCFM at 100 PSIG
  • 1/4" NPT
  • Maximum working pressure, 250 PSIG at 225°F
  • Push-on filter element (included) for quick servicing
  • Pop-up differential indicator signals when element needs replaced
  • Long-lasting elements reduce maintenance costs

Van Air has specialized in compressed air purification for over 60 years. Their compressed air filters have become an industry leader in protecting compressed air dryers, equipment, instrumentation, and processes. Van Air F200 Series compressed air filter housings have set the bar in quality and efficiency to meet today's air filtration needs.

Capacities

FLOW CAPACITIES - SCFM

SELECTING A FILTER

To select the appropriate filter, determine the following conditions regarding the filter installation site:

  • Maximum flow rate
  • Min. and Max. operating pressures
  • Operating temperature
  • Pipe size
  • Degree of filtration desired
  • Contaminants to be removed

Next, refer to the Flow Capacities chart above and locate the column with your lowest operating pressure. Then find the flow rate closest to, but greater than, that of your system. Finally, read across to the left-hand column to determine the filter model that will meet your needs.

You will now need to refer to the Filtration Grades chart, located on the next "Tab". Determine the element grade that meets your needs. Be sure that the maximum inlet temperature listed on the chart is sufficient for your operating conditions.

Refer to the Dimensions and Specifications chart on the last "Tab" above and locate the proper filter model number. Once you have located the model number within the chart, verfiy that the inlet and outlet connections are suitable for your piping. Also make sure that there will be adequate clearance for element replacement.

Filter Grades

Application Element
Grade
Purpose Nominal
Particulate
Removal
Element
Flow
Direction
End Cap
Color Code
Aerosol
Removal
(Liquids)
AA Extra Coarse Coalescing 25.0 m IN / OUT Black
A Coarse Coalescing 5.00 m IN / OUT Green
B General Purpose
Coalescing
1.00 m IN / OUT Red
C High Efficiency
Coalescing
0.01 m IN / OUT Blue
Solid
Particulate
Removal
RAA Extra Coarse Coalescing 25.0 m OUT / IN Black
RA Coarse Coalescing 5.00 m OUT / IN Green
RB General Purpose
Coalescing
1.00 m OUT / IN Red
RC High Efficiency
Coalescing
0.01 m OUT / IN Blue
HT High Temperature
Particulate
1.00 m OUT / IN Zinc Plate
or
Galvanized
Oil Vapor
Removal
RD Vapor Adsorbing 0.01 m OUT / IN Black
Maximum Working Pressure
All Models 250 PSIG
 
Operating Temperature
Minimum 35° F
Maximum 150° F
Maximum Inlet Temperature
AA, A, RAA, RA, RB, & RC Series 225° F
B Series 175° F
C Series 125° F
RD Series 80° F

Specifications

Model Flow1
(SCFM)
In / Out
Conn. (NPT)
Inlet to Outlet Height Weight3
(lbs)
F200-15-1/4-* 15 1/4" 2 3/16 9 1/4 1.4
F200-25-3/8-* 25 3/8" 2 3/16 9 1/4 1.4
F200-25-1/2-* 25 1/2" 2 3/16 9 1/4 1.4
F200-55-1/2-* 55 1/2" 3 7/16 11 3/4 3.5
F200-85-3/4-* 85 3/4" 4 15/16 14 9/16 6.2
F200-100-1-* 100 1" 4 15/16 14 9/16 6.3
F200-150-1-* 150 1" 4 15/16 20 7/16 7.6
F200-265-1-1/4-* 265 1 1/4" 4 15/16 20 7/16 7.7
F200-350-1-1/2-* 350 1 1/2" 5 5/16 21 3/8 9.8
F200-400-2-* 400 2" 5 5/16 21 3/8 9.8
F200-500-2-* 500 2" 5 5/16 29 3/8 12.2
F200-600-3-* 600 3" 7 7/8 24 1/2 22.5
F200-800-3-* 800 3" 7 7/8 30 1/16 25.5
F200-1000-3-* 1,000 3" 7 7/8 34 3/4 32.4
F200-1250-3-* 1250 3" 7 7/8 35 3/4 32.4
F200-1600-3-* 1600 3" 9 1/4 35 3/8 34.7

* Insert appropriate filtration grades here.
1 Flow is based on SCFM @ 100 PSIG @ 100° F.
2 Weight includes housing and elements.

  • Due to continuous improvement, dimensions and specifications may change without notice.
  • Request certified drawing before pre-piping.

BROCHURE

View AllClose

Additional Information

Connection Size:
1/4" NPT
Flow Rate:
15 SCFM @ 100 psig
Maximum Operating Pressure:
250 PSIG
Operating Temperature:
225ºF
Weight:
1.4 Pounds
Inlet to Outlet:
2-13/16"
Height:
9-1/4"
Filter Element Model:
E200-15/25-(*)
Includes:
Pop-Up Pressure Indicator and Manual Ball Valve Drain
View AllClose